The PL11-00 PFI Mill Laboratory Beater is used for laboratory pulp refining, pulp beating and fiber treatment analysis in pulp and paper laboratories. The equipment provides accurate and repeatable refining results according to ISO and TAPPI standards.

Description

VANVEO PL11-00 PFI Mill laboratory pulp beater with stainless steel beating tank

Product Description

The PL11-00 PFI Mill Laboratory Beater, also known as a PFI Mill Refiner, is designed for laboratory pulp refining and fiber treatment analysis in pulp and paper laboratories.

The PFI Mill operates according to ISO 5264/2, TAPPI T248 and GB standards, providing accurate and repeatable laboratory refining results for pulp research, papermaking quality control and fiber analysis applications.

The equipment is suitable for wood pulp, recycled pulp and other fiber materials used in laboratory pulp testing and refining studies. The adjustable beating gap and stable refining pressure help ensure consistent refining performance during laboratory operation.

Manufactured with a rigid machine structure and heavy-duty base, the beater minimizes vibration and maintains stable operation during long-term testing. The high-brightness digital control system supports automatic revolution and time control for standardized laboratory refining cycles.


Key Features

  • Suitable for laboratory pulp refining and pulp beating tests
  • Compliant with ISO 5264/2, TAPPI T248 and GB standards
  • Adjustable beating gap with high precision control
  • Stable refining pressure for repeatable fiber treatment results
  • Automatic revolution and time control system
  • Heavy-duty structure with low vibration operation
  • Suitable for wood pulp and recycled pulp refining
  • High-precision digital display control system

Technical Specifications

Item Specification
Model PL11-00
Pulp Concentration 0 – 50% (Standard: 10%)
Beating Gap Adjustment 0 – 25 mm
Adjustment Accuracy 0.12 mm
Beating Pressure 3.33 N/mm; 1.77 N/mm; 4.89 N/mm
Relative Linear Speed (6.0 ± 0.2) m/s
Beating Tank Size Φ250 mm × 53 mm
Rotor Speed 24.3 r/s
Motor Power 1.1 kW / 380V
Capacity 5 – 40 g bone-dry pulp
Standard Test Capacity 10 g / 450 ml
Dimensions 860 × 450 × 1100 mm
Net Weight 251 kg

Frequently Asked Questions (FAQ)

What is a PFI Mill Refiner?

A PFI Mill Refiner is laboratory equipment used to simulate pulp refining processes under standardized conditions. The PL11-00 PFI Mill Laboratory Beater performs controlled fiber treatment according to ISO 5264/2 and TAPPI T248 standards.

What standards does the equipment comply with?

The equipment complies with ISO 5264/2, TAPPI T248 and GB standards for laboratory pulp refining tests.

What types of pulp can be refined?

The PFI Mill is suitable for wood pulp, recycled pulp and other fiber materials used in papermaking research and laboratory testing.

Why is laboratory pulp refining important?

Laboratory refining helps evaluate fiber treatment performance, drainage characteristics and papermaking properties before industrial production.


Related Paper Testing Equipment

 

More Info

PL28-2 Pulp Disintegrator for laboratory pulp disintegration

Standard Pulp Disintegrator (PL28-2)

The PL28-2 Standard Pulp Disintegrator is designed for laboratory wet disintegration of pulp, separating interwoven fiber bundles into individual fibers while minimizing changes to the original fiber properties.

PL15-A Laboratory Somerville Screen for TAPPI T275 pulp contaminant analysis

Laboratory Somerville Screen (PL15-A)

The PL15-A Laboratory Somerville Screen is used for laboratory pulp screening and contaminant analysis according to TAPPI T275. It efficiently separates shives, stickies and other coarse contaminants from pulp samples for pulp quality control and recycled fiber evaluation.

Laboratory Valley Beater used for pulp beating and fiber treatment evaluation

Laboratory Valley Beater (DJ-WL)

The Laboratory Valley Beater is a standard instrument for pulp beating tests and fiber treatment evaluation. Designed according to ISO 5264-1 and TAPPI T200, it is widely used in pulp and paper laboratories for quality control, research and process development.

PL27 laboratory pulp washing machine for pulp bleaching and pulp washing experiments

PL27 Laboratory Pulp Washing Machine

he PL27 Laboratory Pulp Washing Machine is designed for pulp washing and pulp bleaching experiments in pulp and paper laboratories.

Featuring variable-frequency vibration control and integrated heating function, the equipment provides efficient pulp washing, dispersion and filtration performance for laboratory testing and bleaching research applications.

PL10-A Bauer fiber classifier for pulp fiber length distribution testing in paper laboratory

5-Stage Bauer Fiber Classifier

The PL10-A Bauer Fiber Classifier is used for pulp fiber length distribution analysis through multi-stage screening. It helps paper laboratories evaluate the percentage and distribution of different fiber lengths in pulp samples.

Frequently Asked Questions (FAQ) 1. What is a laboratory sheet press machine used for? It is used to press wet paper sheets in laboratory conditions to improve density, smoothness, and strength before testing. 2. Why is pneumatic pressure used in this machine? Pneumatic systems provide stable, adjustable, and noise-free pressure, which is ideal for laboratory environments. 3. What standard does this machine comply with? This machine complies with QB/T3703-1999, ensuring reliable and standardized paper sample preparation. 4. Can the pressure be adjusted? Yes, the pressure can be adjusted depending on the air compressor settings and testing requirements. 5. Where is this machine commonly used? It is commonly used in paper mills, laboratories, and research institutes for paper quality testing.

Pneumatic Laboratory Sheet Press

The PL8-B Pneumatic Laboratory Sheet Press is used for wet paper sheet pressing and laboratory handsheet preparation in pulp and paper laboratories. The equipment provides stable pneumatic pressure for improving paper sheet density, smoothness and strength during paper testing.

Send Inquiry

Scroll to Top